Flyer

Archives of Clinical Microbiology

  • ISSN: 1989-8436
  • Journal h-index: 24
  • Journal CiteScore: 8.01
  • Journal Impact Factor: 7.55
  • Average acceptance to publication time (5-7 days)
  • Average article processing time (30-45 days) Less than 5 volumes 30 days
    8 - 9 volumes 40 days
    10 and more volumes 45 days
Awards Nomination 20+ Million Readerbase
Indexed In
  • Open J Gate
  • Genamics JournalSeek
  • The Global Impact Factor (GIF)
  • Open Archive Initiative
  • China National Knowledge Infrastructure (CNKI)
  • Directory of Research Journal Indexing (DRJI)
  • OCLC- WorldCat
  • Proquest Summons
  • Publons
  • MIAR
  • University Grants Commission
  • Geneva Foundation for Medical Education and Research
  • Euro Pub
  • Google Scholar
  • Scimago Journal Ranking
  • Secret Search Engine Labs
  • ResearchGate
  • International Committee of Medical Journal Editors (ICMJE)
Share This Page

Validation of live robotic telepathology for intraoperative Neuropathology interpretation at a teriary care center

4th International Conference on Digital Pathology
August 22-23, 2019 Zurich, Switzerland

Aisha Sethi

Dept of Pathology, University of New mexico, Albuquerque, New Mexico

Posters & Accepted Abstracts: Arch Clin Microbiol

Abstract:

Introduction: Digital microcopy (live or whole slide scanning) has significant utility in this era of rapid technological advancements, producing numerous advantages including remote slide review, portability, archiving, training sets which are easily accessible and shareable, for consults, tumor boards, teaching and research. The aim of our study was to validate the use of a robotic live digital microscope for reviewing of intraoperative neuropathology cases to enable remote slide interpretations within our tertiary care center. We hypothesized that interpretation of glass slide is comparable to whole slide imaging for frozen section diagnosis.

Methods:The methodology was determined in keeping with the College of American Pathologists guidelines using a two week “washout period” determining variations in the interpretation of frozen sections using glass slide versus whole slide imaging. Frozen sections and touch prep/smear cytologic preparations from 60 de-identified neuropathology cases were examined. 42 cases were examined by conventional microscopy first followed by remote examination using the VisionTek® M6 Digital Microscope (Sakura Finetek, USA, Inc.). 12 cases were examined with VisionTek first followed by conventional microscopy. Two neuropathologists evaluated the cases and provided interpretations based on the following clinical information: basic clinical history, MRI report, specific site, age and gender. Any discrepancies between glass slide interpretations and live digital interpretations were categorized as major (significant clinical impact) or minor (no significant clinical impact).Both males and females were included in the study. The age ranged from 31- 85 years old(26 males and 28 females). Fourty two cases were reviewed by Pathologist #1 and eighteen cases were reviewed by Pathologist #2.

Results:There were no major discrepancies and only 2 minor discrepancies between live digital and glass slide interpretations.

The two minor discrepancies were as below. One case was called “Cohesive neoplasm with focal necrosis favor atypical meningioma” and the final diagnosis was “Metastatic carcinoma” on permanent sections. The second case was called “malignant tumor favor metastatic carcinoma” on digital review and the glass slide frozen section interpretation was “malignant tumor favor metastatic melanoma”.

Conclusion:Our study validated the use of a robotic live digital microscope for remotely interpreting intraoperative neuropathology specimens at our institution. Although our study had 2 minor discrepancies there were no major discrepancies.With 100% concordance between both methods when evaluating for major discrepancies, live digital microscopy was equivalent to conventional microscopy for intraoperative slide interpretation of neuropathology cases. Hence, the whole slide imaging system can be used effectively for rendering patient diagnosis without compromising patient care in our institution using the current technology.

Biography :

E-mail:

aisethi@salud.unm.edu